PM1703-II series of personal radiation detectors (PRDs) are extremely sensitive and robust devices that detect and locate even trace amounts of radioactive materials.
Equipped with a clip for multiple wearing options and easy to operate even for non-specialists, PRDs became the perfect fit as Radiation Pagers for public security agencies, including border control, rescue teams, police and anti-terrorist units that need to quickly search for radioactive materials in public places.
PM1703MA-II models are gamma-only PRDs equipped with a high-sensitive scintillator for measurement of the personal dose rate up to 300 µSv/h. PM1703MA–II BT model in addition has a Bluetooth module that enables communication with smartphones for advanced operation via the free Polismart® App.
Operation Principle
PM1703MA-II models are gamma-only PRDs equipped with a high-sensitive scintillator for measurement of the personal dose rate up to 300 µSv/h. While ensuring high-performance detection for any scenario, PM1703-II PRD provides confidence in personal safety by continuously monitoring the measured dose equivalent rate and alerting the user with visual, audible and vibration alarms when the pre-set radiation thresholds are exceeded.
Operating history is stored in the instrument‘s non-volatile memory (up to 2000 data points), protecting the data even when the battery is removed. The stored data can also be transferred to a PC via USB. Storing data format is designed to meet the ANSI N42.42.
The PRD features a dedicated operation mode "Mode 0...9" specifically designed for monitoring gamma radiation dose rate within a numerical range. This mode is particularly user-friendly, making it easier for non-professionals to understand and navigate.
Polimaster PRDs offer a significant advantage with their NORM suppression algorithm. This algorithm differentiates alarm signals when there is an increase in natural gamma background values and detection of Naturally Occurring Radioactive Materials (NORM). When NORMs are detected, a green indication light is displayed. However, if other radionuclide types (IND, NUC, MED) are detected, a red indication light and sound alarm are activated. This feature ensures clear and distinct indications based on the specific type of radiation detected.
Models
PM1703MA-II PRD is a basic model.
PM1703MA–II BT PRD is additionally equipped with a Bluetooth module that enables communication with smartphones for advanced operation via the free Polismart® Android App.
Features
- NORM-suppression algorithm for differentiating color-coded alarms triggered by natural or man-made radiation materials
- Dedicated 0-9 scale mode with unitless dose rate indication allowing for ease of use and minimal training
- Free Polismart® iOS and Android app for advanced operation
- USB and Bluetooth (PM1703MA-II BT) communication
- Long-life alkaline or rechargeable battery
- Audible, visual and vibration alarms
- USB and Bluetooth communication
- Shockproof hermetic case IP65
Applications
- Customs and border control
- HAZMAT and CBRNe teams
- Steel and recycling industry
- Waste management sites
- Counter terrorism teams
- Homeland security
- First responders
- Special forces
- Public safety
Detector
|
Csl(TI) SiPM |
Dose rate measurement range
|
0.1 µSv/h to 300 µSv/h |
Dose rate measurement accuracy
|
± 30% |
Energy range
|
60 keV to 1.33 MeV (measurement) 33 keV to 3 MeV (search) |
Gamma radiation sensitivity
|
100 cps per µSv/h (137Cs) 500 cps per µSv/h (241Am) |
Gamma count rate indication range
|
1 to 9999 cps |
Response time
|
0.25 s |
Alarms
|
visual, audible, vibration |
Memory
|
2000 events |
Smartphone communication
|
Bluetooth 4.0 (PM1703MA-IIBT) |
PC communication
|
USB |
Power supply
|
one AA alkaline or rechargeable battery |
Battery lifetime
|
1000 hours |
Ingress protection
|
IP65 |
Drop test
|
0.7 m |
Dimensions
|
87 × 72 × 32 mm |
Weight
|
200 g |
Operating temperature
|
–40 °C to 50 °C |
Atmospheric pressure
|
84 to 106.7 kPa |
Humidity
|
up to 98 % at 35 °C |
Mean service lifetime
|
8 years |