Products
Applications
Support
Company
Purchase

PM5000C Fixed Portal Railway Monitors

Highly sensitive family of Radiation Portal Monitors to monitor a railway line. The portal monitors detect even slightest traces of the hidden radioactive materials and locate a car with radioactive substances.

PM5000C is the latest model of Polimaster`s Portal Monitors Line. PM5000C is designed in a lightweight body and has compact dimensions as well as modern design. High degree of body protection allows operation in the harsh environment and extreme climate conditions.

where to buy

Main advantages of new model are compact dimensions and lightweight body combined with the high sensitivity.

The monitors are designed for installation at customs and border checkpoints to prevent the illicit trafficking of nuclear and radioactive materials. The monitors can be also installed at the areas considered to be potential target for terrorist attack or to monitor limited access areas, such as areas where radioactive materials are used or reprocessed.

The unique feature of the PM5000C Railway Monitors is that they are combine one multipurpose gamma/neutron radiation detector module. Detector modules are mounted on special metal supports with concrete foundations. The railway monitors are equipped with video monitoring systems, computer and pager communication with the specialists, assigned to the radiation monitoring. If necessary, the monitors can be additionally equipped with wheel counters to pin-point the car that caused the alarm.

The monitors are ideally suited to the extreme climatic or environmental condition. They have outstanding performance in the areas with high vibration and electromagnetic interference created by the contact system and the moving trains.

The following configurations of the PM5000C monitors are recommended for railway monitoring:

  • PM5000C-01, PM5000C-01H – two-pillar gamma monitor which consists of 4 gamma radiation detector modules with standard or large volume gamma detectors for higher sensitivity (PM5000C-01H model);
  • PM5000C-10, PM5000C-10H - two-pillar gamma neutron monitor which consists of 4 gamma-neutron radiation detector modules with standard or large volume gamma detectors for higher sensitivity (PM5000C-10H model);
  • PM5000C-14 - two-pillar neutron monitor which consists of 4 neutron detector modules.
Depending on the specific requirements for sensitivity of the monitors, site of installation etc., configurations with a greater number of detector modules can be provided.

Standards compliance

Designed to meet ANSI N42.35 - 2006 , ITRAP+10 (IAEA) requirements

Back to home page

View all Portal Radiation Monitors

PM5000C-01PM5000C-01HPM5000C-10PM5000C-10HPM5000C-14
Weight of Monitor,kg280340560620300
PVT scintillators (gamma detector),
volume (liters) x q-ty
5.3 x 48.8 x 45.3 x 48.8 x 4
Detection zone
(width/height), m.
3.0 x 4
6.0 x 4
6.0 x 4
6.0 x 4
3.0 x 4
6.0 x 4
6.0 x 4
6.0 x 4
3.0 x 4
6.0 x 4
6.0 x 4
Source velocity,
km / h,
no more
5
8
8
20
5
8
8
20
5
8
20
Energy range0.03 - 3 MeV0.03 - 3 MeV0.03 - 3 MeV0.03 - 3 MeV0.03 - 3 MeV
Sensitivity (for 137Cs)
no less, cps/(nSv/h)
2626262626
Lead shield10 mm10 mm10 mm10 mm10 mm
Powerexternal 90-260V AC 50/60Hz
or internal battery (12V) with minimum
8 hours lifetime after external power failure
external 90-260V AC 50/60Hz
or internal battery (12V) with minimum
8 hours lifetime after external power failure
external 90-260V AC 50/60Hz
or internal battery (12V) with minimum
8 hours lifetime after external power failure
external 90-260V AC 50/60Hz
or internal battery (12V) with minimum
8 hours lifetime after external power failure
external 90-260V AC 50/60Hz
or internal battery (12V) with minimum
8 hours lifetime after external power failure
Minimum detectable amounts
of nuclear and radioactive materials
241Am, MBq (µCi)0.7 (18.2)
2.4 (64)
0.7 (18.2)
2.4 (64)
0.7 (18.2)
2.4 (64)
1.8 (49)
2.7 (71)
137Cs, MBq (µCi)0.08 (2.2)
0.28 (7.6)
0.08 (2.2)
0.28 (7.6)
0.08 (2.2)
0.28 (7.6)
0.21 (5.7)
0.31 (8.4)
60Co, MBq (µCi)0.045 (1.2)
0.15 (4)
0.045 (1.2)
0.15 (4)
0.045 (1.2)
0.15 (4)
0.12 (3.2)
0.17 (4.6)
235U, g32
105
32
105
32
105
80
120
238U, g480
1700
480
1700
480
1700
1300
1900
239Pu, g0.9
3.1
0.9
3.1
0.9
3.1
2.3
3.4
239Pu, (4cm Pb), gx-80
200
200
330
80
200
330
252Cf, neutrons/sx-5000
12000
12000
24000
5000
12000
21000
Environmental Characteristics
Temperature - 30 up to + 50 C- 30 to + 50 C- 30 to + 50 C- 30 до + 50 C- 30 to + 50 C
Humidity up to 100%to 100%to 100%до to 100%up to 100%
Atmospheric pressurefrom 84 to106,7from 84 to 106,7from 84 to 106,7от 84 до 106,7from 84 to 106,7
Environmental protectionIP55IP55IP55IP55IP55

Product Brochures: