Products
Applications
Support
Company
Purchase

Radiation monitor PM5000B

Portal monitors of PM5000B Series are designed to detect radioactive and nuclear materials transported through a control zone. RPMs are used to detect RNM in vehicles and luggage.

Monitors have modular design and may have one-pillar or two-pillar configurations, adaptable height and width according to customer`s requirements. Monitors can be equipped with video monitoring system.


where to buy

 

Distinctive features:

  • High sensitivity
  • Advanced data processing algorithms
  • Modular design
  • Easy-in-use
  • Audible and light alarms
  • Indoor and outdoor installations
  • Reliable, automatic, 24/7 operation
  • PC connection through the Ethernet port
  • Video monitoring system (option)
  • Integration into a nuclear protection network  controlled by a central PC (option) with further integration into higher level networks controlled by an Expert Center (option)

 

The following configurations of PM5000B Series are recommended for use as vehicle portal monitors:

  • РМ5000В-01 - two-pillar gamma monitor which consists of 4 gamma radiation detector modules;
  • РМ5000В-05 - two-pillar gamma monitor which consists of 2 gamma radiation detector modules;
  • РМ5000В-09 - two-pillar gamma-neutron monitor which consists of 2 gamma-neutron radiation detector modules on the basis of 10B / ZnS (Ag);
  • РМ5000В-10 - two-pillar gamma-neutron monitor which consists of 4 gamma and 4 neutron radiation detector modules on the basis of 10B / ZnS (Ag);
  • РМ5000В-13 - two-pillar neutron monitor which consists of 2 neutron detector modules on the basis of 10B / ZnS (Ag);
  • РМ5000В-14 - two-pillar neutron monitor which consists of 4 neutron detector modules on the basis of 10B / ZnS (Ag);
  • РМ5000В-16 - two-pillar gamma monitor which consists of 8 gamma radiation detector modules;

 

Application:

  • Airports
  • Seaports
  • Railway stations
  • Customs and border checkpoints
  • Nuclear plants and other facilities of the nuclear industry
  • Nuclear waste disposal and storage sites
  • Scrap metal industry
  • Governmental offices, banks and post offices

 

Standards compliance

Designed to meet ANSI N42.35 - 2006 , ITRAP+10 (IAEA) requirements

 

Back to home page

View all Portal Radiation Monitors

 

Applications:


PM5000B-01PM5000B-05PM5000B-09PM5000B-10PM5000B-13PM5000B-14PM5000B-16
Weight of Monitor,kgno more than 1100no more than 1100no more than 1100no more than 1100no more than 1100no more than 1100no more than 1100
Type of registered radiationgammagammagamma-neutrongamma-neutronneutronneutrongamma
Accuracy of gamma detection unitxxxxxxx
Accuracy of neutron detection unitxxxxxxx
Detection zone
(width/height), m.
3.0 x 4.5
6.0 x 4.5
3.0 x 2
6.0 x 2
3.0 x 2
6.0 x 2
6.0x4.5
6.0x4.5
3.0 x 2
6.0 x 2
3.0 x 4.5
6.0 x 4.5
6.0 x 4.5
6.0 x 4.5
6.0 x 4.5
Source velocity,
km / h,
no more
5
8
5
8
5
8
8
20
5
8
5
8
20
8
20
Energy range0,02 - 3,0 MeV0,02 - 3,0 MeV0,02 - 3,0 MeV0,02 - 3,0 MeV0,02 - 3,0 MeV0,02 - 3,0 MeV0,02 - 3,0 MeV
Power60 VA60 VA60 VA60 VA60 VA60 VA60 VA
Minimum detectable amounts
of nuclear and radioactive materials
241Am, MBq (µCi)1.29 (35)
1.9 (51)
0,46 (12)
1.8 (49)
0,46 (12)
1.8 (49)
1,29 (35)
1,9 (51)
xx1,0 (27)
1,5 (39)
137Cs, MBq (µCi)0.21 (5,7)
0.31 (8,4)
0,08 (2,2)
0,29 (7,8)
0,08 (2,2)
0,29 (7,8)
0,21 (5,7)
0,31 (8,4)
xx0,16 (4,4)
0,24 (6,5)
60Co, MBq (µCi)0.12 (3,2)
0.17 (4,6)
0,045 (1,2)
0,16 (4,3)
0,045 (1,2)
0,16 (4,3)
0,12 (3,2)
0,17 (4,6)
xx0,09 (2,5)
0,13 (3,5)
235U, g1300
1900
460
1800
460
1800
1300
1900
xx1000
1500
238U, g80
120
32
110
32
110
80
120
xx62
92
239Pu, g2.3
3.4
0,9
3,2
0,9
3,2
2,3
3,4
xx1,9
2,8
239Pu, (4cm Pb), gxx85
250
160
280
85
250
60
160
280
x
252Cf, neutrons/sxx5000
15000
9300
17000
5000
15000
3300
9300
17000
x
Environmental Characteristics
Temperature -30 up to +50°Cfrom -30 up to +50 °Cfrom -30 up to +50 °Cfrom -30 up to +50 °Cfrom -30 up to +50 °Cfrom -30 up to +50 °Cfrom -30 up to +50 °C
Humidity up to 100 % at 35°C and lower, no moistureup to 100 % at 35°C and lower, no moisture up to 100 % at 35°C and lower, no moistureup to 100 % at 35°C and lower, no moistureup to 100 % at 35°C and lower, no moistureup to 100 % at 35°C and lower, no moistureup to 100 % at 35°C and lower, no moisture
Atmospheric pressurefrom 84 to 106.7 kPafrom 84 to 106.7 kPafrom 84 to 106.7 kPafrom 84 to 106.7 kPafrom 84 to 106.7 kPafrom 84 to 106.7 kPafrom 84 to 106.7 kPa
Environmental protectionIP55IP55IP55IP55IP55IP55IP55

Operation manuals:



Product Brochures: