Radiation monitor PM5000B

Portal monitors of PM5000B Series are designed to detect radioactive and nuclear materials transported through a control zone.

PM5000B-10 and PM5000B-16 modifications are recommended for detection of RNM in railway transport.

Monitors have modular design and may have one-pillar or two-pillar configurations, adaptable height and width according to customer`s requirements. Monitors can be equipped with video monitoring system.


where to buy

 

Monitored objects:

  • Trains

 

The following configurations of PM5000B Series are recommended for use as railway portal monitors:

  • РМ5000В-10 - two-pillar gamma-neutron monitor which consists of 4 gamma and 4 neutron radiation detector modules on the basis of 10B / ZnS (Ag)
  • РМ5000В-16 - two-pillar gamma monitor which consists of 8 gamma radiation detector modules

 

Distinctive features:

  • High sensitivity
  • Advanced data processing algorithms
  • Modular design
  • Easy-in-use
  • Audible and light alarms
  • Indoor and outdoor installations
  • Reliable, automatic, 24/7 operation
  • PC connection through the Ethernet port
  • Video monitoring system (option)
  • Integration into a nuclear protection network  controlled by a central PC (option) with further integration into higher level networks controlled by an Expert Center (option)

 

Standards compliance

Designed to meet ANSI N42.35 - 2006 , ITRAP+10 (IAEA) requirements

PM5000B-10PM5000B-16
Weight of Monitor,kgno more then 1100no more then 1100
Type of registered radiationgamma-neutrongamma
Accuracy of gamma detection unitxx
Accuracy of neutron detection unitxx
Detection zone
(width/height), m.
6.0x4.5
6.0x4.5
6.0 x 4.5
6.0 x 4.5
Source velocity,
km / h,
no more
8
20
8
20
Energy range0.02 - 3.0 MeV0.02 - 3.0 MeV
Powerexternal 115-230V AC 47/63Hz
or internal battery (12V) with minimum
8 hours lifetime after external power failure
external 115-230V AC 47/63Hz
or internal battery (12V) with minimum
8 hours lifetime after external power failure
Minimum detectable amounts
of nuclear and radioactive materials
241Am, MBq (µCi)1.5 (41)
2.3 (62)
1.15 (31)
1.8 (49)
137Cs, MBq (µCi)0.16 (4.3)
0.24 (6.5)
0.125 (3.4)
0.185 (5)
60Co, MBq (µCi)0.10 (2.7)
0.15 (4.1)
0.075 (2)
0.115 (3.1)
57Co, MBq (µCi)0.200 (5.4)
0.300 (8.1)
0.155 (4.2)
0.230 (6.2)
133Ba, MBq (µCi)

0.10 (2.7)
0.15 (4.1)
0.075 (2)
0.115 (3.1)
235U, g80
120
62
92
238U, g1300
1900
1000
1500
239Pu, g2.3
3.4
1.9
2.8
239Pu, (4cm Pb), g240
400
x
252Cf, neutrons/s14000
24000
x
Environmental Characteristics
Temperature from -30 up to +50 °Cfrom -30 up to +50 °C
Humidity up to 98 % at 40°C and lower, no moistureup to 98 % at 40°C and lower, no moisture
Atmospheric pressurefrom 84 to 106.7 kPafrom 84 to 106.7 kPa
Environmental protectionIP65IP65