Radiation monitor PM5000P

Radiation Monitors of PM5000P Series are designed to detect radioactive and nuclear materials in vehicles and luggage at various checkpoints.

Polimaster offers radiation monitors of different configuration to fulfill wide range of customer`s needs.
where to buy

Radiation Monitors can be installed at vehicular, railway and pedestrian border crossings, at customs checkpoints to prevent the illicit penetration of the radioactive sources into the country or the limited-access areas, checkpoints of Nuclear power plants (NPP`s), nuclear industry facilities, nuclear waste disposal and storage sites, check points in banks, offices.

Radiation monitors may have one-pillar or two-pillar configurations depending on the site requirements, and can be installed both indoor or outdoor.

 Monitors of PM5000P Series are designed to monitor gamma or neutron or both gamma and neutron radiation. Monitors can be also equipped with video monitoring systems, computer and pager communication/notification system to ensure prompt assess to the experts, assigned to radiation monitoring tasks.

 There are several configurations of the PM5000P monitors that are recommended for use as the pedestrian monitors:

  • PM5000P - one-pillar gamma monitor with increased sensitivity due to use of detectors of larger volume
  • PM5000P-01 - two-pillar gamma monitor
  • PM5000P-02B - one-pillar gamma-neutron monitor (neutron detector is based on the one solid-state detector (10B/ZnS(Ag))
  • PM5000P-03B - two-pillar gamma-neutron monitor (neutron detector is based on the one solid-state detector (10B/ZnS(Ag))

Application:

  • Cross border checkpoints
  • Customs check points
  • NPP`s checkpoints
  • Nuclear industry facilities
  • Nuclear waste disposal and storage sites
  • Metallurgical facilities
  • Mining sites
  • Public events sites
  • Checkpoints in banks, offices

 

 

PM5000PPM5000P-01PM5000P-02BPM5000P-03B
Weight of Monitor,kg125245135265
Type of registered radiationgammagammagamma-neutrongamma-neutron
Detection zone
(width/height), m.
1×2
1.5×2
1x2
1.5x2
1x2
1.5x2
1x2
1.5x2
Source velocity,
km / h,
no more
5555
Energy range0.02 - 3.0 MeV0.02 - 3.0 MeV0.02 - 3.0 MeV0.02 - 3.0 MeV
Powerexternal 90-260V AC 50/60Hz
or internal battery (12V) with minimum
8 hours lifetime after external power failure
from 115 to 230 V industrial AC network
(from 85 to 264 V range)
up to 8 hours from built-in accumulator battery
from 115 to 230 V industrial AC network
(from 85 to 264 V range)
up to 8 hours from built-in accumulator battery
from 115 to 230 V industrial AC network
(from 85 to 264 V range)
up to 8 hours from built-in accumulator battery
Minimum detectable amounts
of nuclear and radioactive materials
241Am, MBq (µCi)0.4 (11)
0.7 (19)
0.12 (3.2)
0.175 (4.75)
0.75 (20)
1.29 (35)
0.2 (5.5)
0.33 (8.75)
137Cs, MBq (µCi)0.08 (2)
0.13 (3.5)
0.022 (0.59)
0.033 (0.88)
0.12 (3.2)
0.21 (5.6)
0.032 (0.87)
0.048 (1.3)
60Co, MBq (µCi)0.04 (1.1)
0.07 (1.9)
0.012 (0.32)
0.0175 (0.475)
0,65 (1.8)
0.11 (3)
0.018 (0.47)
0.026 (0.71)
235U, g30
50
8.5
12.5
47
80
13.4
20
238U, g470
815
140
205
870
1500
250
380
239Pu, g0.8
1.4
0.24
0.36
1.4
2.3
0.4
0.6
239Pu, (4cm Pb), gxx110
188
42
62
252Cf, neutrons/sxx6500
11250
2500
3700
Environmental Characteristics
Temperature -30... +50 °C-30....+50°C-30....+50°C-30....+50°C
Humidity up to 100% at 35 °C up to 100 %up to 100 %up to 100 %
Atmospheric pressurefrom 84 to 106,7 kPafrom 84 up to 106.7 kPafrom 84 up to 106.7 kPafrom 84 up to 106.7 kPa
Environmental protectionIP55IP55IP55IP55

Operation manuals:



Product Brochures: